You are here

CMC in field "electricity and magnetism"

Quantity: DC resistance standards and sources: low values
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
DCR01 (1.0E-5 - 1) Ω (0,06 - 50) µΩ/Ω
  • oil bath temperature 23 (20) °C
111-MP-C004
Quantity: DC resistance standards and sources: intermediate values
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
DCR02 (10 - 1.0E+6) Ω (0,02 - 4) µΩ/Ω
  • oil bath temperature 23 (20) °C
111-MP-C004
Quantity: DC resistance standards and sources: high values
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
DCR03 (1.0E+7 - 1.0E+14) Ω (7 - 6000) µΩ/Ω
  • air bath temperature 23 °C
  • voltage 20 V to 100 V, 500 V, 1000 V
111-MP-C002
Quantity: DC resistance meters: low values
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
DCR07 (0.0001 - 1) W (5 - 50) µW/W
  • air bath temperature 23 (20) °C
111-MP-C004
Quantity: DC resistance meters: intermediate values
Interní identifikátor Range Calibration and measurement capabilities Procedures
DCR08 (1 - 1.0E+9) W (3 - 100) µW/W 111-MP-C001
Quantity: DC resistance meters: high values
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
DCR09 (1.0E+9 - 1.0E+12) W (250 - 1000) µW/W
  • air bath temperature 23 (20) °C
111-MP-C002
Quantity: AC resistance: real component
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
ACR01 (1 - 1.0E+4) W (20 - 20) µW/W
  • frequency 40 Hz to 10 kHz
111-MP-C001
Quantity: DC voltage
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.1 (0 - 20) mV (15μV/V+0,050 μV - 15μV/V+0,050 μV) 611-MP-C097, 611-MP-C098
9.1 (0 - 20) mV (15μV/V+0,050 μV - 15μV/V+0,050 μV) 611-MP-C097, 611-MP-C098
9.1 (20 - 200) mV (5 - 5) μV/V 611-MP-C097, 611-MP-C098
9.1 (20 - 200) mV (5 - 5) μV/V 611-MP-C097, 611-MP-C098
9.1 (0.2 - 2) V (2.6 - 2,6) μV/V 611-MP-C097, 611-MP-C098
9.1 (0.2 - 2) V (2.6 - 2,6) μV/V 611-MP-C097, 611-MP-C098
9.1 (2 - 20) V (2.1 - 2,1) μV/V 611-MP-C097, 611-MP-C098
9.1 (2 - 20) V (2.1 - 2,1) μV/V 611-MP-C097, 611-MP-C098
9.1 (10 - ) V 0.15 μV/V 611-MP-C097, 611-MP-C098
9.1 (10 - ) V 0.15 μV/V 611-MP-C097, 611-MP-C098
9.1 (20 - 1100) V (2.9 - 2,9) μV/V 611-MP-C097, 611-MP-C098
9.1 (20 - 1100) V (2.9 - 2,9) μV/V 611-MP-C097, 611-MP-C098
Quantity: AC voltage
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.2 (0.9 - 2) mV (2000 - 2000) μV/V
  • frequency 10 Hz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (2000 - 2000) μV/V
  • frequency 10 Hz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (3100 - 3100) μV/V
  • frequency 75 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (3100 - 3100) μV/V
  • frequency 75 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (3300 - 3300) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (3300 - 3300) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (3500 - 3500) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (3500 - 3500) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (360 - 360) μV/V
  • frequency 10 Hz up to 25 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (360 - 360) μV/V
  • frequency 10 Hz up to 25 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (330 - 330) μV/V
  • frequency 25 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (330 - 330) μV/V
  • frequency 25 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (530 - 530) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (530 - 530) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (710 - 710) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (710 - 710) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (790 - 790) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (790 - 790) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (1100 - 1100) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (1100 - 1100) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (98 - 98) μV/V
  • frequency 10 Hz up to 25 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (98 - 98) μV/V
  • frequency 10 Hz up to 25 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (190 - 190) μV/V
  • frequency 25 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (190 - 190) μV/V
  • frequency 25 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (370 - 370) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (370 - 370) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (590 - 590) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (590 - 590) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (650 - 650) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (650 - 650) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (1000 - 1000) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (1000 - 1000) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (37 - 37) μV/V
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (37 - 37) μV/V
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (26 - 26) μV/V
  • frequency 35 Hz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (26 - 26) μV/V
  • frequency 35 Hz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (33 - 33) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (33 - 33) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (40 - 40) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (40 - 40) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (110 - 110) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (110 - 110) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (210 - 210) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (210 - 210) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (560 - 560) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (560 - 560) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (37 - 37) μV/V
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (37 - 37) μV/V
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (26 - 26) μV/V
  • frequency 35 Hz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (26 - 26) μV/V
  • frequency 35 Hz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (33 - 33) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (33 - 33) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (40 - 40) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (40 - 40) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (110 - 110) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (110 - 110) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (210 - 210) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (210 - 210) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (560 - 560) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (560 - 560) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (42 - 42) μV/V
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (42 - 42) μV/V
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (37 - 37) μV/V
  • frequency 35 Hz up to 175 Hz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (37 - 37) μV/V
  • frequency 35 Hz up to 175 Hz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (28 - 28) μV/V
  • frequency 175 Hz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (28 - 28) μV/V
  • frequency 175 Hz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (40 - 40) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (40 - 40) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (71 - 71) μV/V
  • frequency 75 kHz up to 150 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (71 - 71) μV/V
  • frequency 75 kHz up to 150 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (240 - 240) μV/V
  • frequency 150 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (240 - 240) μV/V
  • frequency 150 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (40 - 40) μV/V
  • frequency 10 Hz up to 5 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (40 - 40) μV/V
  • frequency 10 Hz up to 5 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (45 - 45) μV/V
  • frequency 5 kHz up to 25 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (45 - 45) μV/V
  • frequency 5 kHz up to 25 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (76 - 76) μV/V
  • frequency 25 kHz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (76 - 76) μV/V
  • frequency 25 kHz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (120 - 120) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (120 - 120) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (350 - 350) μV/V
  • frequency 75 kHz up to 100 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (350 - 350) μV/V
  • frequency 75 kHz up to 100 kHz
611-MP-C097, 611-MP-C098
Quantity: DC current
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.3 (0 - 1) μA (0.1 - 0,1) nA 611-MP-C097, 611-MP-C098
9.3 (0 - 1) μA (0.1 - 0,1) nA 611-MP-C097, 611-MP-C098
9.3 (1 - 100) μA (21.10-6.I - 21.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (1 - 100) μA (21.10-6.I - 21.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (100 - 200) μA (12.10-6.I - 12.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (100 - 200) μA (12.10-6.I - 12.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (0.2 - 2000) mA (6.10-6.I - 6.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (0.2 - 2000) mA (6.10-6.I - 6.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (2 - 20) A (15.10-6.I - 15.10-6.I) 611-MP-C097
9.3 (20 - 100) A (20.10-6.I - 20.10-6.I) 611-MP-C097
9.3 (0 - 1) μA (0.1 - 0,1) nA 611-MP-C097, 611-MP-C098
9.3 (0 - 1) μA (0.1 - 0,1) nA 611-MP-C097, 611-MP-C098
9.3 (1 - 100) μA (21.10-6.I - 21.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (1 - 100) μA (21.10-6.I - 21.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (100 - 200) μA (15.10-6.I - 15.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (100 - 200) μA (15.10-6.I - 15.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (0.2 - 20) mA (6.10-6.I - 6.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (0.2 - 20) mA (6.10-6.I - 6.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (20 - 200) mA (8.10-6.I - 8.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (20 - 200) mA (8.10-6.I - 8.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (0.2 - 2) A (15.10-6.I - 15.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (0.2 - 2) A (15.10-6.I - 15.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (2 - 20) A (30.10-6.I - 30.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (2 - 20) A (30.10-6.I - 30.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (20 - 100) A (50.10-6.I - 50.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (20 - 100) A (50.10-6.I - 50.10-6.I) 611-MP-C097, 611-MP-C098
(0.001 - 2000) nA (0.01 - 1) % 611-MP-C098
Quantity: AC current
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.4 (9 - 200) μA (130 - 130) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (130 - 130) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (120 - 120) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (120 - 120) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (99 - 99) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (99 - 99) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (160 - 160) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (160 - 160) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (120 - 120) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (120 - 120) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (110 - 110) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (110 - 110) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (89 - 89) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (89 - 89) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (140 - 140) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (140 - 140) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (120 - 120) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (120 - 120) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (100 - 100) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (100 - 100) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (85 - 85) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (85 - 85) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (140 - 140) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (140 - 140) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (120 - 120) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (120 - 120) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (100 - 100) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (100 - 100) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (85 - 85) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (85 - 85) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (140 - 140) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (140 - 140) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (170 - 170) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (170 - 170) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (160 - 160) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (160 - 160) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (120 - 120) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (120 - 120) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (220 - 220) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (220 - 220) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (310 - 310) μA/A
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (310 - 310) μA/A
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (280 - 280) μA/A
  • frequency 35 Hz up to 2 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (280 - 280) μA/A
  • frequency 35 Hz up to 2 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (400 - 400) μA/A
  • frequency 2 kHz up to 7,5 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (400 - 400) μA/A
  • frequency 2 kHz up to 7,5 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (690 - 690) μA/A
  • frequency 7,5 kHz up to 15 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (690 - 690) μA/A
  • frequency 7,5 kHz up to 15 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (1600 - 1600) μA/A
  • frequency 15 kHz up to 20 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (1600 - 1600) μA/A
  • frequency 15 kHz up to 20 kHz
611-MP-C097, 611-MP-C098
Quantity: DC resistance
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.5 (0.0001 - 0.0001) Ω (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.0001 - 0.0001) Ω (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.0001 - 0.0001) Ω (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.0001 - 0.0001) Ω (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.001 - 0.001) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.001 - 0.001) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.001 - 0.001) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.001 - 0.001) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.01 - 0.01) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.01 - 0.01) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.01 - 0.01) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.01 - 0.01) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.02 - 0.02) Ω (2.2 - 2.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.02 - 0.02) Ω (2.2 - 2.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.02 - 0.02) Ω (2.2 - 2.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.02 - 0.02) Ω (2.2 - 2.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.1 - 0.1) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.1 - 0.1) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.1 - 0.1) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.1 - 0.1) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (25 - 25) Ω (0.63 - 0.63) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (25 - 25) Ω (0.63 - 0.63) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (25 - 25) Ω (0.63 - 0.63) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (25 - 25) Ω (0.63 - 0.63) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) GΩ (100 - 100) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) GΩ (100 - 100) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) GΩ (100 - 100) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) GΩ (100 - 100) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) GΩ (500 - 500) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) GΩ (500 - 500) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) GΩ (500 - 500) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) GΩ (500 - 500) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0 - 0.1) mΩ (3,5 µΩ/Ω + 0,5 nΩ - 3,5 µΩ/Ω + 0,5 nΩ) 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0 - 0.1) mΩ (3,5 µΩ/Ω + 0,5 nΩ - 3,5 µΩ/Ω + 0,5 nΩ) 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0 - 0.1) mΩ (3,5 µΩ/Ω + 0,5 nΩ - 3,5 µΩ/Ω + 0,5 nΩ) 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0 - 0.1) mΩ (3,5 µΩ/Ω + 0,5 nΩ - 3,5 µΩ/Ω + 0,5 nΩ) 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) mΩ (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) mΩ (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) mΩ (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) mΩ (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.0002 - 0.001) Ω (6 - 6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.0002 - 0.001) Ω (6 - 6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.0002 - 0.001) Ω (6 - 6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.0002 - 0.001) Ω (6 - 6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.001 - 0.002) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.001 - 0.002) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.001 - 0.002) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.001 - 0.002) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.002 - 0.01) Ω (5.6 - 5.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.002 - 0.01) Ω (5.6 - 5.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.002 - 0.01) Ω (5.6 - 5.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.002 - 0.01) Ω (5.6 - 5.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.01 - 0.02) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.01 - 0.02) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.01 - 0.02) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.01 - 0.02) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.02 - 0.1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.02 - 0.1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.02 - 0.1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.02 - 0.1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.2 - 1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.2 - 1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.2 - 1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.2 - 1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) Ω (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) Ω (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) Ω (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) Ω (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) Ω (0.93 - 0.93) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) Ω (0.93 - 0.93) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) Ω (0.93 - 0.93) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) Ω (0.93 - 0.93) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) kΩ (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) kΩ (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) kΩ (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) kΩ (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) kΩ (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) kΩ (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) kΩ (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) kΩ (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) kΩ (4.1 - 4.1) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) kΩ (4.1 - 4.1) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) kΩ (4.1 - 4.1) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) kΩ (4.1 - 4.1) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) MΩ (7.4 - 7.4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) MΩ (7.4 - 7.4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) MΩ (7.4 - 7.4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) MΩ (7.4 - 7.4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 200) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 200) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 200) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 200) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) MΩ (520 - 520) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) MΩ (520 - 520) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) MΩ (520 - 520) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) MΩ (520 - 520) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) GΩ (120 - 120) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) GΩ (120 - 120) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) GΩ (120 - 120) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) GΩ (120 - 120) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) GΩ (0.52 - 0.52) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) GΩ (0.52 - 0.52) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) GΩ (0.52 - 0.52) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) GΩ (0.52 - 0.52) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) GΩ (0.12 - 0.12) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) GΩ (0.12 - 0.12) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) GΩ (0.12 - 0.12) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) GΩ (0.12 - 0.12) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
Quantity: phase angle
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(0 - 360) ° (0.1 - 0.1) °
  • frequency 50 Hz
611-MP-C060
Quantity: temperature (calibration by electrical simulation)
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.10 (-50 - 1760) °C (0.12 - 0.12) °C 611-MP-C130
9.10 (-50 - 1760) °C (0.16 - 0.16) °C 611-MP-C130
9.10 (0 - 1820) °C (0.14 - 0.14) °C 611-MP-C130
9.10 (-210 - 1200) °C (0.04 - 0.04) °C 611-MP-C130
9.10 (-270 - 400) °C (0.04 - 0.04) °C 611-MP-C130
9.10 (-270 - 1000) °C (0.04 - 0.04) °C 611-MP-C130
9.10 (-270 - 1370) °C (0.05 - 0.05) °C 611-MP-C130
9.10 (-270 - 1300) °C (0.05 - 0.05) °C 611-MP-C130
9.10 (-200 - 100) °C (0.03 - 0.03) °C 611-MP-C130
9.10 (-200 - 900) °C (0.04 - 0.04) °C 611-MP-C130
9.10 (-200 - 800) °C (0.03 - 0.03) °C 611-MP-C130
9.10 (0 - 2500) °C (0.24 - 0.24) °C 611-MP-C130
9.10 (-200 - 850) °C (0.02 - 0.02) °C 611-MP-C130
9.10 (-200 - 850) °C (0.02 - 0.02) °C 611-MP-C130
9.10 (-200 - 850) °C (0.03 - 0.03) °C 611-MP-C130
9.10 (-200 - 850) °C (0.02 - 0.02) °C 611-MP-C130
9.10 (-60 - 250) °C (0.01 - 0.01) °C 611-MP-C130
9.10 (-60 - 250) °C (0.01 - 0.01) °C 611-MP-C130
Quantity: capacity
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(0.01 - 1.0E+4) nF (0.05 - 0.2) %
  • frequency 100 Hz up to 20 kHz
611-MP-C041
(0.00019 - 1000) μF (0.1 - 0.3) %
  • frequency 100 Hz up to 1 kHz
611-MP-C030
(0.00035 - 1000) μF (0.3 - 1) %
  • frequency 100 Hz up to 1 kHz
611-MP-C041
Quantity: AC resistance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(0.0001 - 1.0E+4) kΩ (0.05 - 0.2) %
  • frequency 100 Hz up to 20 kHz
611-MP-C041
Quantity: inductance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(0.1 - 10) H (0.5 - 1) %
  • frequency 100 Hz up to 20 kHz
611-MP-C041
Quantity: current
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.21 (1 - 1000) A (0.8 - 0.8) %
  • frequency 0 Hz
131-MP-C006
9.21 (1 - 1000) A (0.5 - 0.5) %
  • frequency 50 Hz
131-MP-C006
Quantity: insulation resistance
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (0.01 - 100) MΩ (0.0012 - 0.0012) % 131-MP-C006
9.21 (0.1 - 1) GΩ (0.0017 - 0.0017) % 131-MP-C006
9.21 (1 - 10) GΩ (0.0017 - 0.0086) % 131-MP-C006
9.21 (10 - 100) GΩ (0.0086 - 0.034) % 131-MP-C006
9.21 (0.1 - 1) TΩ (0.034 - 0.27) % 131-MP-C006
9.21 (1.0E+10 - 1) GΩ (0.02 - 0.02) % 131-MP-C006
9.21 (1 - 10) GΩ (1 - 1) % 131-MP-C006
9.21 (0.35 - 100) GΩ (1.2 - 1.5) % 131-MP-C006
9.21 (0.1 - 1) TΩ (2.5 - 2.5) % 131-MP-C006
9.21 (1 - 10) TΩ (4 - 4) % 131-MP-C006
9.21 (100 - 100) MΩ (0.002 - 0.002) % 131-MP-C006
9.21 (1 - 1) GΩ (0.003 - 0.003) % 131-MP-C006
(0.01 - 100) TΩ (0.02 - 1) % 131-MP-C006
Quantity: ochranná smyčka, impedance sítě a zemní smyčka
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (25 - 25) mΩ (5 - 5) mΩ 131-MP-C006
9.21 (50 - 50) mΩ (5 - 5) mΩ 131-MP-C006
9.21 (100 - 100) mΩ (5 - 5) mΩ 131-MP-C006
9.21 (330 - 330) mΩ (7 - 7) mΩ 131-MP-C006
9.21 (500 - 500) mΩ (8 - 8) mΩ 131-MP-C006
9.21 (1 - 1) Ω (10 - 10) mΩ 131-MP-C006
9.21 (1.8 - 1.8) Ω (18 - 18) mΩ 131-MP-C006
9.21 (5 - 5) Ω (30 - 30) mΩ 131-MP-C006
9.21 (10 - 10) Ω (60 - 60) mΩ 131-MP-C006
9.21 (18 - 18) Ω (100 - 100) mΩ 131-MP-C006
9.21 (50 - 50) Ω (300 - 300) mΩ 131-MP-C006
9.21 (100 - 100) Ω (500 - 500) mΩ 131-MP-C006
9.21 (180 - 180) Ω (1 - 1) Ω 131-MP-C006
9.21 (500 - 500) Ω (2.5 - 2.5) Ω 131-MP-C006
9.21 (1 - 1) kΩ (5 - 5) Ω 131-MP-C006
9.21 (1.8 - 1.8) kΩ (10 - 10) Ω 131-MP-C006
Quantity: RCD trip current
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (3 - 3000) mA (0.02 - 0.02) % 131-MP-C006
9.21 (3 - 3000) mA (1 - 1) % 131-MP-C006
Quantity: RCD trip time
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (10 - 5000) ms (0,02%+0,25ms - 0,02%+0,25ms) 131-MP-C006
9.21 (10 - 5000) ms (0.05 - 0.05) ms 131-MP-C006
Quantity: leakage current passive
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (0.1 - 30) mA (0,3%+2mA - 0,3%+2mA) 131-MP-C006
Quantity: leakage current differential
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (0.1 - 30) mA (0,3%+2mA - 0,3%+2mA) 131-MP-C006
Quantity: leakage current substitute
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (0.1 - 30) mA (0,3%+2mA - 0,3%+2mA) 131-MP-C006
Quantity: leakage current active
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (0.1 - 30) mA (0,3%+1mA - 0,3%+1mA) 131-MP-C006
9.21 (0.1 - 30) mA (0.055 - 0.055) % 131-MP-C006
Quantity: high voltage
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.21 (0 - 10) kV (0,3%+5V - 0,3%+5V)
  • frequency 0 Hz
131-MP-C006
9.21 (0 - 10) kV (0,5%+5V - 0,5%+5V)
  • frequency 50 Hz
131-MP-C006
Quantity: vertical deflection factor
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.22 (1 - 21) mV (0,1% MH + 15mV - 0,1% MH + 15mV)
  • frequency 10 Hz up to 10 kHz
113-MP-C008
9.22 (21 - 556) mV (0,1% MH + 1mV - 0,1% MH + 1mV)
  • frequency 10 Hz up to 10 kHz
113-MP-C008
9.22 (0.556 - 210) V (0,05% MH + 1mV - 0,05% MH + 1mV)
  • frequency 10 Hz up to 10 kHz
113-MP-C008
Quantity: time base
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.23 (1.0E-9 - 50) s (2.5E-7 - 2.5E-7) 113-MP-C008
Quantity: bandwidth
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.24 (0 - 100) MHz (3 - 3) % 113-MP-C008
9.24 (0 - 550) MHz (6 - 6) % 113-MP-C008
9.24 (0 - 1.1) GHz (8 - 8) % 113-MP-C008
Quantity: rise time
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.25 (300 - 300) ps (12 - 12) ps 113-MP-C008
Quantity: střídavý výkon
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(0.0005 - 60) kW (0.024 - 0.13) %
  • frequency (50) Hz
  • voltage (10 up to 600) V
  • current (0,05 up to 100) A
  • cos φ 0,2 up to 1
611-MP-C042
Quantity: module impedance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(1 - 1000) mΩ (0.002 - 0.02) %
  • frequency 50 Hz up to 1 kHz
611-MP-C040
Quantity: electromagnetic fields above 50 kHz: electric field strength
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
EMF11 (0.01 - 200) V/m (0,4 - 1) dB
  • frequency 50 kHz to 18 GHz
113-MP-C006
Quantity: electromagnetic fields above 50 kHz: power flux density
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
EMF13 (0.1 - 10) mW/cm2 (1 - 1) dB
  • frequency 2450 MHz
113-MP-C006
Quantity: RF power: absolute power in coaxial
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF01 (5.0E-7 - 20) W (4 - 65) mW/W
  • frequency 0 GHz to 18 GHz
  • connector 50 Ω
113-MP-C010
Quantity: RF power: absolute power in waveguide
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF02 (5.0E-7 - 1) W (15 - 50) mW/W
  • frequency 8,2 GHz to 18 GHz
  • connector R100, R140
113-MP-C010
Quantity: RF power: calibration factor in coaxial line
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF03 (0.7 - 1,1) (0,004 - 0,015)
  • frequency 0 GHz to 18 GHz
113-MP-C010
Quantity: Scalar RF reflection coefficient: in waveguide
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF08 (0 - 1) (0.02 - 0,02)
  • frequency 26,5 GHz to 40 GHz
  • connector R320
113-MP-C010
Quantity: Scalar RF attenuation: in coaxial line
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF09 (0 - 110) dB ( 0,02 - 0,57) dB
  • frequency 0,001 GHz to 18 GHz
  • connector 50 Ω
113-MP-C010
Quantity: Scalar RF attenuation: in waveguide
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF10 (0 - 110) dB (0,07 - 0,57) dB
  • frequency 8 GHz to 40 GHz
  • connector R100, R140, R220, R320
113-MP-C010
Quantity: Scattering parameters: reflection coefficient (Sii) in coaxial line, magnitude
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF13a (0 - 1) (0,002 - 0,038)
  • frequency 0.1 MHz to 18 GHz
  • connector N-type, PC-7, PC-3.5
113-MP-C009
Quantity: Scattering parameters: reflection coefficient (Sii) in coaxial line, phase
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF13b (-180 - 180) ° (0,11 - 180) °
  • frequency 0.1 MHz to 18 GHz
  • connector N-type, PC-7, PC-3.5
113-MP-C009
Quantity: Scattering parameters: transmission coefficient (Sij) in coaxial line, magnitude
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF15a (0.0003 - 1) (0,00003 - 0,003)
  • frequency 0.010 GHz to 18 GHz
  • connector N-type, PC-7, PC-3.5
113-MP-C009
Quantity: Scattering parameters: transmission coefficient (Sij) in coaxial line, phase
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF15b (-180 - 180) ° (0,59 - 6) °
  • frequency 0.010 GHz to 18 GHz
  • connector N-type, PC-7, PC-3.5
113-MP-C009
Quantity: Scattering parameters: effective source match
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF17 (0 - 1) (0,008 - 0,03)
  • frequency 0.1 MHz to 18 GHz
  • connector 50 W, 75 W
113-MP-C009
Quantity: antenna properties: antenna gain
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF25 (0 - 28) dB (0.25 - 0,25) dB
  • frequency 1 GHz to 18 GHz
113-MP-C010
Quantity: RF voltage and current: RF voltage sources
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF33 (0.1 - 7) V (4 - 11) mV/V
  • frequency 0 GHz to 2 GHz
  • connector 50 Ω
113-MP-C010, 113-MP-C011
RF33 (0.1 - 7) V (4 - 11) mV/V
  • frequency 0 GHz to 2 GHz
  • connector 50 Ω
113-MP-C010, 113-MP-C011
Quantity: RF voltage and current: RF voltage meters
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
RF34 (0.1 - 7) V (4,5 - 15) mV/V
  • frequency 0 GHz to 2 GHz
  • connector 50 Ω
113-MP-C010, 113-MP-C011
RF34 (0.1 - 7) V (4,5 - 15) mV/V
  • frequency 0 GHz to 2 GHz
  • connector 50 Ω
113-MP-C010, 113-MP-C011
Quantity: voltage
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.27 (0.01 - 10) V (1.5 - 1.5) % MH
  • frequency 0,1 MHz up to 2 GHz
113-MP-C014
Quantity: vertical deflection factor
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.22 (1 - 21) mV (0,1% MH + 15mV - 0,1% MH + 15mV)
  • frequency 10 Hz up to 10 kHz
113-MP-C008
9.22 (21 - 556) mV (0,1% MH + 1mV - 0,1% MH + 1mV)
  • frequency 10 Hz up to 10 kHz
113-MP-C008
9.22 (0.556 - 210) V (0,05% MH + 1mV - 0,05% MH + 1mV)
  • frequency 10 Hz up to 10 kHz
113-MP-C008
Quantity: time base
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.23 (1.0E-9 - 50) s (2.5E-7 - 2.5E-7) 113-MP-C008
Quantity: bandwidth
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.24 (0 - 100) MHz (3 - 3) % 113-MP-C008
9.24 (0 - 550) MHz (6 - 6) % 113-MP-C008
9.24 (0 - 1.1) GHz (8 - 8) % 113-MP-C008
Quantity: rise time
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.25 (300 - 300) ps (12 - 12) ps 113-MP-C008
Quantity: hf power: power sensor calibration factor
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.26 (0.05 - 1.1) (0.9 - 0.9) %MH
  • frequency 0 GHz up to 1 GHz
113-MP-C014
9.26 (0.05 - 1.1) (1.5 - 1.5) %MH
  • frequency 1 GHz up to 18 GHz
113-MP-C014
9.26 (0.05 - 1.1) (2 - 2) %MH
  • frequency 18 GHz up to 40 GHz
113-MP-C014
Quantity: hf power
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.26 (-100 - -50) dBm (0,19-0,0012 (MH+50) - 0,19-0,0012 (MH+50)) dB
  • frequency 0,1 MHz up to 4,2 GHz
113-MP-C014
9.26 (-50 - 20) dBm (0.1 - 0.1) dB
  • frequency 0,1 MHz up to 4,2 GHz
113-MP-C014
9.26 (-100 - -50) dBm (0,29-0,005 (MH+50) - 0,29-0,005 (MH+50)) dB
  • frequency 4,2 GHz up to 18 GHz
113-MP-C014
9.26 (-50 - 20) dBm (0.15 - 0.15) dB
  • frequency 4,2 GHz up to 18 GHz
113-MP-C014
9.26 (-90 - -50) dBm (0,44-0,0027 (MH+50) - 0,44-0,0027 (MH+50)) dB
  • frequency 18 GHz up to 26,5 GHz
113-MP-C014
9.26 (-50 - 20) dBm (0.15 - 0.15) dB
  • frequency 18 GHz up to 40 GHz
113-MP-C014
9.26 (20 - 43) dBm (0.17 - 0.17) dB
  • frequency 0,01 GHz up to 18 GHz
113-MP-C014
9.26 (43 - 53) dBm (0.17 - 0.17) dB
  • frequency 0,01 GHz up to 1 GHz
113-MP-C014
9.28 (20 - -20) dBm (0.17 - 0.17) dB
  • frequency 0,1 MHz up to 6 GHz
113-MP-C014
9.28 (-20 - -60) dBm (0.22 - 0.22) dB
  • frequency 0,1 MHz up to 6 GHz
113-MP-C014
Quantity: hf power ratio (attenuation, gain)
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.26 (0 - 55) dB (0,015+0,0005 MH - 0,015+0,0005 MH) dB
  • frequency 0,1 MHz up to 26,5 GHz
113-MP-C014
9.26 (55 - 75) dB (0,046+0,0005 MH - 0,046+0,0005 MH) dB
  • frequency 0,1 MHz up to 26,5 GHz
113-MP-C014
9.26 (75 - 90) dB (0,12+0,0047 (MH-75) - 0,12+0,0047 (MH-75)) dB
  • frequency 0,1 MHz up to 18 GHz
113-MP-C014
9.26 (75 - 90) dB (0,12+0,019 (MH-75) - 0,12+0,019 (MH-75)) dB
  • frequency 18 GHz up to 26,5 GHz
113-MP-C014
9.26 (90 - 100) dB (0,12+0,012 (MH-90) - 0,12+0,012 (MH-90)) dB
  • frequency 0,1 MHz up to 13,2 GHz
113-MP-C014
9.26 (0 - 40) dB (0.1 - 0.1) dB
  • frequency 26,5 GHz up to 40 GHz
113-MP-C014
Quantity: antenna factor
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
(-60 - 90) dB (0.14 - 1) dB
  • frequency 10 Hz to 30 MHz
113-MP-C016
Quantity: DC voltage sources: single values
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
DCV01 (1 - 10) V (0,06 - 0,1) µV/V
  • fixed voltage 1 V, 1,018 V, 10 V
611-MP-C031
Quantity: DC voltage sources: low values
Interní identifikátor Range Calibration and measurement capabilities Procedures
DCV02 (0.001 - 10) V (0,051 - 8) µV 611-MP-C097
Quantity: DC voltage sources: intermediate values
Interní identifikátor Range Calibration and measurement capabilities Procedures
DCV03 (10 - 1100) V (0,8 - 1,6) µV/V 611-MP-C097
Quantity: DC voltage meters: very low values
Interní identifikátor Range Calibration and measurement capabilities Procedures
DCV05 (0 - 1) mV (100 - 100) nV 611-MP-C097
Quantity: DC voltage meters: intermediate values
Interní identifikátor Range Calibration and measurement capabilities Procedures
DCV06 (0,001 - 1100) V (0,1 - 2200) µV 611-MP-C097
Quantity: DC resistance standards and sources: multiple ranges
Interní identifikátor Range Calibration and measurement capabilities Procedures
DCR05 (1 - 1.0E+8) W (1,5 - 55) µW/W 611-MP-C097
Quantity: DC current sources: intermediate values
Interní identifikátor Range Calibration and measurement capabilities Procedures
DCA02 (0.0001 - 20) A (6 - 15) µA/A 611-MP-C097
Quantity: DC current sources: high values
Interní identifikátor Range Calibration and measurement capabilities Procedures
DCA03 (20 - 100) A (20 - 20) µA/A 611-MP-C097
Quantity: DC current meters: intermediate values
Interní identifikátor Range Calibration and measurement capabilities Procedures
DCA07 (0,0001 - 20) A (11 - 54) µA/A 611-MP-C098
Quantity: capacitance: low loss capacitors
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
CAP01a (1 - 1.0E+4) pF (0,5 - 20) µF/F
  • frequency 1 kHz
611-MP-C030
Quantity: capacitance: dissipation factor for low loss capacitors
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
CAP01b (1.0E-6 - 1) (3 - 300) 1.0E-6
  • capacitance 1 pF to 10 nF
  • frequency 1 kHz
611-MP-C030
Quantity: capacitance: dielectric capacitors
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
CAP02a (10 - 1.0E+4) nF 50 µF/F
  • frequency 1 kHz
611-MP-C030
Quantity: capacitance: dissipation factor for dielectric capacitors
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
CAP02b (1.0E-6 - 1) (40 - 400) 1.0E-6
  • capacitance 10 nF to 1000 nF
  • frequency 1 kHz
611-MP-C030
Quantity: inductance: self inductance, low values
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
IND01 (10 - 1000) µH (500 - 500) µH/H
  • frequency 1 kHz
611-MP-C099
Quantity: inductance: self inductance, intermediate values
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
IND02 (1 - 1000) mH (20 - 50) µH/H
  • frequency 1 kHz
611-MP-C099
Quantity: AC voltage: AC-DC transfer difference at low voltages
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
ACV01 (0.001 - 0.5) V (10 - 325) µV/V
  • frequency 10 Hz to 1 MHz
611-MP-C032
Quantity: AC voltage: AC-DC transfer difference at medium voltages
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
ACV02 (0.5 - 5) V (5 - 45) µV/V
  • frequency 10 Hz to 1 MHz
611-MP-C032
Quantity: AC voltage: AC-DC transfer difference at higher voltages
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
ACV03 (5 - 1000) V (10 - 100) µV/V
  • frequency 10 Hz to 1 MHz
611-MP-C032
Quantity: AC voltage up to 1000 V: sources
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
ACV04 (0.001 - 1000) V (12 - 600) µV/V
  • frequency 10 Hz to 1 MHz
611-MP-C097
Quantity: AC voltage up to 1000 V: meters
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
ACV05 (0.001 - 1100) V (24 - 1100) µV/V
  • frequency 10 Hz to 1 MHz
611-MP-C098
Quantity: AC voltage ratio: real component
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
ACV06 (1.0E-6 - 1) (5.0E-7 - 5.0E-5)
  • frequency 400 Hz to 10 kHz
  • maximum voltage 50 V
611-MP-C124
Quantity: AC current up to 100 A: sources
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
ACA02 (0.0001 - 10) A (65 - 180) µA/A
  • frequency 10 Hz to 10 kHz
611-MP-C098
Quantity: AC current up to 100 A: meters
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
ACA03 (0.0001 - 20) A (75 - 1500) µA/A
  • frequency 10 Hz to 10 kHz
611-MP-C098
Quantity: AC power and energy: single phase (f <= 400 Hz), active power
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
ACP01 (2.5 - 3.0E+4) W (0.1 - 0.1) mW/VA
  • voltage 50 V to 300 V
  • current 0.05 A to 100 A
  • power factor 1 to 0.5, inductive or capacitive
  • frequency 45 Hz to 65 Hz
611-MP-C042
Quantity: AC power and energy: three phase, active power
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
ACP03 (7.5 - 9.0E+4) W (0.2 - 0.2) mW/VA
  • voltage 50 V to 300 V
  • current 0.05 A to 100 A
  • power factor 1 to 0.5, inductive or capacitive
  • frequency 45 Hz to 65 Hz
611-MP-C042
Quantity: Current and voltage waveform: voltage harmonic distortion
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
SIG07a (0.0005 - 40) % (6,5E-06 - 10) %
  • frequency first harmonic 20 Hz to 100 kHz
  • frequency higher harmonic 20 Hz to 500 kHz
  • voltage 0.1 V to 100 V
611-MP-C087
SIG07b (0.0005 - 40) % ((5E-06 + 3E-03THD), THD in % - (5E-06 + 3E-03THD), THD in %) %
  • frequency first harmonic 20 Hz to 100 kHz
  • frequency higher harmonic 20 Hz to 1 MHz
  • voltage 1 V to 5 V
611-MP-C087
Quantity: DC voltage
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.1 (0 - 20) mV (15μV/V+0,050 μV - 15μV/V+0,050 μV) 611-MP-C097, 611-MP-C098
9.1 (0 - 20) mV (15μV/V+0,050 μV - 15μV/V+0,050 μV) 611-MP-C097, 611-MP-C098
9.1 (20 - 200) mV (5 - 5) μV/V 611-MP-C097, 611-MP-C098
9.1 (20 - 200) mV (5 - 5) μV/V 611-MP-C097, 611-MP-C098
9.1 (0.2 - 2) V (2.6 - 2,6) μV/V 611-MP-C097, 611-MP-C098
9.1 (0.2 - 2) V (2.6 - 2,6) μV/V 611-MP-C097, 611-MP-C098
9.1 (2 - 20) V (2.1 - 2,1) μV/V 611-MP-C097, 611-MP-C098
9.1 (2 - 20) V (2.1 - 2,1) μV/V 611-MP-C097, 611-MP-C098
9.1 (10 - ) V 0.15 μV/V 611-MP-C097, 611-MP-C098
9.1 (10 - ) V 0.15 μV/V 611-MP-C097, 611-MP-C098
9.1 (20 - 1100) V (2.9 - 2,9) μV/V 611-MP-C097, 611-MP-C098
9.1 (20 - 1100) V (2.9 - 2,9) μV/V 611-MP-C097, 611-MP-C098
9.1a (0 - 2) V (1,5.10-6.U+0,05 μV - 1,5.10-6.U+0,05 μV) 611-MP-C005
9.1a (2 - 20) V (0,8.10-6.U - 0,8.10-6.U) 611-MP-C005
9.1a (20 - 1100) V (1,6.10-6.U - 1,6.10-6.U) 611-MP-C005
9.1a (0 - 2) V (2,2.10-6.U+0,10 μV - 2,2.10-6.U+0,10 μV) 611-MP-C005
9.1a (2 - 20) V (1,6.10-6.U - 1,6.10-6.U) 611-MP-C005
9.1a (10 - ) V 0,15.10-6.U 611-MP-C005
9.1a (20 - 1100) V (2,0.10-6.U - 2,0.10-6.U) 611-MP-C005
Quantity: AC voltage
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.2 (0.9 - 2) mV (2000 - 2000) μV/V
  • frequency 10 Hz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (2000 - 2000) μV/V
  • frequency 10 Hz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (3100 - 3100) μV/V
  • frequency 75 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (3100 - 3100) μV/V
  • frequency 75 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (3300 - 3300) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (3300 - 3300) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (3500 - 3500) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (0.9 - 2) mV (3500 - 3500) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (360 - 360) μV/V
  • frequency 10 Hz up to 25 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (360 - 360) μV/V
  • frequency 10 Hz up to 25 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (330 - 330) μV/V
  • frequency 25 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (330 - 330) μV/V
  • frequency 25 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (530 - 530) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (530 - 530) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (710 - 710) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (710 - 710) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (790 - 790) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (790 - 790) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (1100 - 1100) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) mV (1100 - 1100) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (98 - 98) μV/V
  • frequency 10 Hz up to 25 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (98 - 98) μV/V
  • frequency 10 Hz up to 25 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (190 - 190) μV/V
  • frequency 25 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (190 - 190) μV/V
  • frequency 25 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (370 - 370) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (370 - 370) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (590 - 590) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (590 - 590) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (650 - 650) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (650 - 650) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (1000 - 1000) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) mV (1000 - 1000) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (37 - 37) μV/V
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (37 - 37) μV/V
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (26 - 26) μV/V
  • frequency 35 Hz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (26 - 26) μV/V
  • frequency 35 Hz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (33 - 33) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (33 - 33) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (40 - 40) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (40 - 40) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (110 - 110) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (110 - 110) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (210 - 210) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (210 - 210) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (560 - 560) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (0.2 - 2) V (560 - 560) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (37 - 37) μV/V
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (37 - 37) μV/V
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (26 - 26) μV/V
  • frequency 35 Hz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (26 - 26) μV/V
  • frequency 35 Hz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (33 - 33) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (33 - 33) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (40 - 40) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (40 - 40) μV/V
  • frequency 75 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (110 - 110) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (110 - 110) μV/V
  • frequency 200 kHz up to 400 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (210 - 210) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (210 - 210) μV/V
  • frequency 400 kHz up to 750 kHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (560 - 560) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (2 - 20) V (560 - 560) μV/V
  • frequency 750 kHz up to 1 MHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (42 - 42) μV/V
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (42 - 42) μV/V
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (37 - 37) μV/V
  • frequency 35 Hz up to 175 Hz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (37 - 37) μV/V
  • frequency 35 Hz up to 175 Hz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (28 - 28) μV/V
  • frequency 175 Hz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (28 - 28) μV/V
  • frequency 175 Hz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (40 - 40) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (40 - 40) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (71 - 71) μV/V
  • frequency 75 kHz up to 150 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (71 - 71) μV/V
  • frequency 75 kHz up to 150 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (240 - 240) μV/V
  • frequency 150 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (20 - 200) V (240 - 240) μV/V
  • frequency 150 kHz up to 200 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (40 - 40) μV/V
  • frequency 10 Hz up to 5 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (40 - 40) μV/V
  • frequency 10 Hz up to 5 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (45 - 45) μV/V
  • frequency 5 kHz up to 25 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (45 - 45) μV/V
  • frequency 5 kHz up to 25 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (76 - 76) μV/V
  • frequency 25 kHz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (76 - 76) μV/V
  • frequency 25 kHz up to 40 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (120 - 120) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (120 - 120) μV/V
  • frequency 40 kHz up to 75 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (350 - 350) μV/V
  • frequency 75 kHz up to 100 kHz
611-MP-C097, 611-MP-C098
9.2 (200 - 1100) V (350 - 350) μV/V
  • frequency 75 kHz up to 100 kHz
611-MP-C097, 611-MP-C098
9.2a (0.1 - 1) μV (0.5 - 0.5) %
  • frequency 50 Hz up to 200 Hz
611-MP-C061
9.2a (0.1 - 1) μV (0.2 - 0.2) %
  • frequency 0,2 kHz up to 10 kHz
611-MP-C061
9.2a (0.1 - 1) μV (0.7 - 0.7) %
  • frequency 10 kHz up to 100 kHz
611-MP-C061
9.2a (1 - 1000) μV (0.2 - 0.2) %
  • frequency 50 Hz up to 200 Hz
611-MP-C061
9.2a (1 - 1000) μV (0.07 - 0.07) %
  • frequency 0,2 kHz up to 10 kHz
611-MP-C061
9.2a (1 - 1000) μV (0.3 - 0.3) %
  • frequency 10 kHz up to 100 kHz
611-MP-C061
Quantity: DC current
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.3 (0 - 1) μA (0.1 - 0,1) nA 611-MP-C097, 611-MP-C098
9.3 (0 - 1) μA (0.1 - 0,1) nA 611-MP-C097, 611-MP-C098
9.3 (1 - 100) μA (21.10-6.I - 21.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (1 - 100) μA (21.10-6.I - 21.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (100 - 200) μA (12.10-6.I - 12.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (100 - 200) μA (12.10-6.I - 12.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (0.2 - 2000) mA (6.10-6.I - 6.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (0.2 - 2000) mA (6.10-6.I - 6.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (2 - 20) A (15.10-6.I - 15.10-6.I) 611-MP-C097
9.3 (20 - 100) A (20.10-6.I - 20.10-6.I) 611-MP-C097
9.3 (0 - 1) μA (0.1 - 0,1) nA 611-MP-C097, 611-MP-C098
9.3 (0 - 1) μA (0.1 - 0,1) nA 611-MP-C097, 611-MP-C098
9.3 (1 - 100) μA (21.10-6.I - 21.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (1 - 100) μA (21.10-6.I - 21.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (100 - 200) μA (15.10-6.I - 15.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (100 - 200) μA (15.10-6.I - 15.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (0.2 - 20) mA (6.10-6.I - 6.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (0.2 - 20) mA (6.10-6.I - 6.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (20 - 200) mA (8.10-6.I - 8.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (20 - 200) mA (8.10-6.I - 8.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (0.2 - 2) A (15.10-6.I - 15.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (0.2 - 2) A (15.10-6.I - 15.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (2 - 20) A (30.10-6.I - 30.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (2 - 20) A (30.10-6.I - 30.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (20 - 100) A (50.10-6.I - 50.10-6.I) 611-MP-C097, 611-MP-C098
9.3 (20 - 100) A (50.10-6.I - 50.10-6.I) 611-MP-C097, 611-MP-C098
Quantity: AC current
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.4 (9 - 200) μA (130 - 130) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (130 - 130) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (120 - 120) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (120 - 120) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (99 - 99) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (99 - 99) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (160 - 160) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (9 - 200) μA (160 - 160) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (120 - 120) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (120 - 120) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (110 - 110) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (110 - 110) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (89 - 89) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (89 - 89) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (140 - 140) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) mA (140 - 140) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (120 - 120) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (120 - 120) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (100 - 100) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (100 - 100) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (85 - 85) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (85 - 85) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (140 - 140) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) mA (140 - 140) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (120 - 120) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (120 - 120) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (100 - 100) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (100 - 100) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (85 - 85) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (85 - 85) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (140 - 140) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (20 - 200) mA (140 - 140) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (170 - 170) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (170 - 170) μA/A
  • frequency 10 Hz up to 25 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (160 - 160) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (160 - 160) μA/A
  • frequency 25 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (120 - 120) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (120 - 120) μA/A
  • frequency 35 Hz up to 1 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (220 - 220) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (0.2 - 2) A (220 - 220) μA/A
  • frequency 1 kHz up to 10 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (310 - 310) μA/A
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (310 - 310) μA/A
  • frequency 10 Hz up to 35 Hz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (280 - 280) μA/A
  • frequency 35 Hz up to 2 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (280 - 280) μA/A
  • frequency 35 Hz up to 2 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (400 - 400) μA/A
  • frequency 2 kHz up to 7,5 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (400 - 400) μA/A
  • frequency 2 kHz up to 7,5 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (690 - 690) μA/A
  • frequency 7,5 kHz up to 15 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (690 - 690) μA/A
  • frequency 7,5 kHz up to 15 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (1600 - 1600) μA/A
  • frequency 15 kHz up to 20 kHz
611-MP-C097, 611-MP-C098
9.4 (2 - 20) A (1600 - 1600) μA/A
  • frequency 15 kHz up to 20 kHz
611-MP-C097, 611-MP-C098
Quantity: DC resistance
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.5 (0.0001 - 0.0001) Ω (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.0001 - 0.0001) Ω (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.0001 - 0.0001) Ω (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.0001 - 0.0001) Ω (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.001 - 0.001) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.001 - 0.001) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.001 - 0.001) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.001 - 0.001) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.01 - 0.01) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.01 - 0.01) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.01 - 0.01) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.01 - 0.01) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.02 - 0.02) Ω (2.2 - 2.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.02 - 0.02) Ω (2.2 - 2.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.02 - 0.02) Ω (2.2 - 2.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.02 - 0.02) Ω (2.2 - 2.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.1 - 0.1) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.1 - 0.1) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.1 - 0.1) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (0.1 - 0.1) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (25 - 25) Ω (0.63 - 0.63) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (25 - 25) Ω (0.63 - 0.63) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (25 - 25) Ω (0.63 - 0.63) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (25 - 25) Ω (0.63 - 0.63) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (100 - 100) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) GΩ (100 - 100) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) GΩ (100 - 100) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) GΩ (100 - 100) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (1 - 1) GΩ (100 - 100) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) GΩ (500 - 500) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) GΩ (500 - 500) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) GΩ (500 - 500) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.5 (10 - 10) GΩ (500 - 500) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0 - 0.1) mΩ (3,5 µΩ/Ω + 0,5 nΩ - 3,5 µΩ/Ω + 0,5 nΩ) 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0 - 0.1) mΩ (3,5 µΩ/Ω + 0,5 nΩ - 3,5 µΩ/Ω + 0,5 nΩ) 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0 - 0.1) mΩ (3,5 µΩ/Ω + 0,5 nΩ - 3,5 µΩ/Ω + 0,5 nΩ) 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0 - 0.1) mΩ (3,5 µΩ/Ω + 0,5 nΩ - 3,5 µΩ/Ω + 0,5 nΩ) 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) mΩ (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) mΩ (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) mΩ (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) mΩ (7.2 - 7.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.0002 - 0.001) Ω (6 - 6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.0002 - 0.001) Ω (6 - 6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.0002 - 0.001) Ω (6 - 6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.0002 - 0.001) Ω (6 - 6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.001 - 0.002) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.001 - 0.002) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.001 - 0.002) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.001 - 0.002) Ω (3.5 - 3.5) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.002 - 0.01) Ω (5.6 - 5.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.002 - 0.01) Ω (5.6 - 5.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.002 - 0.01) Ω (5.6 - 5.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.002 - 0.01) Ω (5.6 - 5.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.01 - 0.02) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.01 - 0.02) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.01 - 0.02) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.01 - 0.02) Ω (2.6 - 2.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.02 - 0.1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.02 - 0.1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.02 - 0.1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.02 - 0.1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.1 - 0.2) Ω (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.2 - 1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.2 - 1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.2 - 1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (0.2 - 1) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) Ω (0.73 - 0.73) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) Ω (1.6 - 1.6) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) Ω (0.71 - 0.71) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) Ω (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) Ω (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) Ω (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) Ω (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) Ω (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) Ω (0.93 - 0.93) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) Ω (0.93 - 0.93) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) Ω (0.93 - 0.93) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) Ω (0.93 - 0.93) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) kΩ (0.35 - 0.35) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) kΩ (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) kΩ (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) kΩ (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) kΩ (1.2 - 1.2) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) kΩ (0.38 - 0.38) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) kΩ (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) kΩ (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) kΩ (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 100) kΩ (0.86 - 0.86) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (100 - 200) kΩ (0.59 - 0.59) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) kΩ (4.1 - 4.1) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) kΩ (4.1 - 4.1) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) kΩ (4.1 - 4.1) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) kΩ (4.1 - 4.1) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) MΩ (4 - 4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) MΩ (7.4 - 7.4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) MΩ (7.4 - 7.4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) MΩ (7.4 - 7.4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) MΩ (7.4 - 7.4) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) MΩ (7 - 7) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 200) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 200) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 200) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (20 - 200) MΩ (16 - 16) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) MΩ (520 - 520) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) MΩ (520 - 520) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) MΩ (520 - 520) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (200 - 1000) MΩ (520 - 520) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) GΩ (120 - 120) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) GΩ (120 - 120) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) GΩ (120 - 120) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (1 - 2) GΩ (120 - 120) μΩ/Ω 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) GΩ (0.52 - 0.52) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) GΩ (0.52 - 0.52) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) GΩ (0.52 - 0.52) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (2 - 10) GΩ (0.52 - 0.52) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) GΩ (0.12 - 0.12) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) GΩ (0.12 - 0.12) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) GΩ (0.12 - 0.12) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
9.6 (10 - 20) GΩ (0.12 - 0.12) % 611-MP-C097, 611-MP-C098, 131-MP-C003, 131-MP-C005
Quantity: ratio
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.6a (0 - 1.1) (8.0E-7 - 8.0E-7)
  • frequency (0 up to 400) Hz
611-MP-C045
9.6a (1.1 - 4) (2.0E-6 - 2.0E-6)
  • frequency (0 up to 400) Hz
611-MP-C045
Quantity: AC active electrical power
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.7 (5 - 216) kW (0.01 - 0.01) %
  • frequency (15 up to 800) Hz
  • voltage (1 up to 600) V
  • current (0,005 up to 120) A
  • cos φ 0,1 up to 1
611-MP-C042
Quantity: AC reactive electrical power
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.7a (5 - 216) kvar (0.02 - 0.02) %
  • frequency (15 up to 800) Hz
  • voltage (1 up to 600) V
  • current (0,005 up to 120) A
  • sin φ 0,1 up to 1
611-MP-C042
Quantity: phase angle
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.7b (0 - 360) ° (0.1 - 0.1)
  • frequency (0,4 up to 1,592) kHz
  • voltage (0,1 up to 1) μV
611-MP-C061
9.7b (0 - 360) ° (0.05 - 0.05)
  • frequency (0,4 up to 1,592) kHz
  • voltage (1 up to 100) μV
611-MP-C061
9.7b (0 - 360) ° (0.1 - 0.1)
  • frequency (0,4 up to 1,592) kHz
  • voltage (0,1 up to 1) mV
611-MP-C061
9.7b (0 - 360) ° (0.05 - 0.05)
  • frequency (0,4 up to 1,592) kHz
  • voltage (1 up to 10) mV
611-MP-C061
9.7b (0 - 360) ° (0.001 - 0.001) °
  • frequency (0,001 up to 6) kHz
  • voltage (0,01 up to 100) V
611-MP-C042
9.7b (0 - 360) ° (0.002 - 0.002) °
  • frequency (6 up to 50) kHz
  • voltage (0,01 up to 100) V
611-MP-C042
9.7b (0 - 360) ° (0.05 - 0.05) °
  • frequency (50 up to 100) kHz
  • voltage (0,01 up to 100) V
611-MP-C042
9.7b (0 - 360) ° (0.05 - 0.05) °
  • frequency (0,1 up to 1) MHz
  • voltage (0,01 up to 1) V
611-MP-C042
9.7b (0 - 360) ° (0.1 - 0.1) °
  • frequency (1 up to 10) MHz
  • voltage (0,01 up to 1) V
611-MP-C042
Quantity: flicker
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.8 (0.5 - 5) Pst (0,003xPst - 0,003xPst)
  • frequency 50 Hz
611-MP-C043
Quantity: pH (electrical simulation)
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.9 (0 - 14) pH (0.001 - 0.001) pH 611-MP-C129
9.9 (-1000 - 1000) mV (0.01 - 0.01) mV 611-MP-C129
Quantity: temperature (calibration by electrical simulation)
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.10 (-50 - 1760) °C (0.12 - 0.12) °C 611-MP-C130
9.10 (-50 - 1760) °C (0.16 - 0.16) °C 611-MP-C130
9.10 (0 - 1820) °C (0.14 - 0.14) °C 611-MP-C130
9.10 (-210 - 1200) °C (0.04 - 0.04) °C 611-MP-C130
9.10 (-270 - 400) °C (0.04 - 0.04) °C 611-MP-C130
9.10 (-270 - 1000) °C (0.04 - 0.04) °C 611-MP-C130
9.10 (-270 - 1370) °C (0.05 - 0.05) °C 611-MP-C130
9.10 (-270 - 1300) °C (0.05 - 0.05) °C 611-MP-C130
9.10 (-200 - 100) °C (0.03 - 0.03) °C 611-MP-C130
9.10 (-200 - 900) °C (0.04 - 0.04) °C 611-MP-C130
9.10 (-200 - 800) °C (0.03 - 0.03) °C 611-MP-C130
9.10 (0 - 2500) °C (0.24 - 0.24) °C 611-MP-C130
9.10 (-200 - 850) °C (0.02 - 0.02) °C 611-MP-C130
9.10 (-200 - 850) °C (0.02 - 0.02) °C 611-MP-C130
9.10 (-200 - 850) °C (0.03 - 0.03) °C 611-MP-C130
9.10 (-200 - 850) °C (0.02 - 0.02) °C 611-MP-C130
9.10 (-60 - 250) °C (0.01 - 0.01) °C 611-MP-C130
9.10 (-60 - 250) °C (0.01 - 0.01) °C 611-MP-C130
Quantity: capacity
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.11 (10 - 100) pF (0,5.10-6.C - 0,5.10-6.C)
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) pF (0,5.10-6.C - 0,5.10-6.C)
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) pF (0.015 - 0.015) %
  • frequency (50 up to 200) Hz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) pF (0.015 - 0.015) %
  • frequency (50 up to 200) Hz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) pF (0.007 - 0.007) %
  • frequency (0,2 up to 1) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) pF (0.007 - 0.007) %
  • frequency (0,2 up to 1) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) pF (0.0015 - 0.0015) %
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) pF (0.0015 - 0.0015) %
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) pF (0.005 - 0.005) %
  • frequency (1 up to 5) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) pF (0.005 - 0.005) %
  • frequency (1 up to 5) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) pF (0.01 - 0.01) %
  • frequency (0,005 up to 1) MHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) pF (0.01 - 0.01) %
  • frequency (0,005 up to 1) MHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) pF (0.2 - 0.2) %
  • frequency (1 up to 10) MHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) pF (0.2 - 0.2) %
  • frequency (1 up to 10) MHz
611-MP-C030, 611-MP-C041
9.11 (10 - 1000) pF (0.005 - 0.005) %
  • frequency (0,05 up to 1) kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 1000) pF (0.005 - 0.005) %
  • frequency (0,05 up to 1) kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 1000) pF (0.0007 - 0.0007) %
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 1000) pF (0.0007 - 0.0007) %
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 1000) pF (0.005 - 0.005) %
  • frequency (1 up to 10) kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 1000) pF (0.005 - 0.005) %
  • frequency (1 up to 10) kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 1000) pF (0.01 - 0.01) %
  • frequency (0,01 up to 1) MHz
611-MP-C030, 611-MP-C041
9.11 (10 - 1000) pF (0.01 - 0.01) %
  • frequency (0,01 up to 1) MHz
611-MP-C030, 611-MP-C041
9.11 (10 - 1000) pF (0.2 - 0.2) %
  • frequency (1 up to 10) MHz
611-MP-C030, 611-MP-C041
9.11 (10 - 1000) pF (0.2 - 0.2) %
  • frequency (1 up to 10) MHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) nF (0.01 - 0.01) %
  • frequency (50 up to 200) Hz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) nF (0.01 - 0.01) %
  • frequency (50 up to 200) Hz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) nF (0.007 - 0.007) %
  • frequency (0,2 up to 1) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) nF (0.007 - 0.007) %
  • frequency (0,2 up to 1) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) nF (0.001 - 0.001) %
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) nF (0.001 - 0.001) %
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) nF (0.007 - 0.007) %
  • frequency (1 up to 5) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) nF (0.007 - 0.007) %
  • frequency (1 up to 5) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) nF (0.01 - 0.01) %
  • frequency (0,05 up to 1) MHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) nF (0.01 - 0.01) %
  • frequency (0,05 up to 1) MHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) nF (0.2 - 0.2) %
  • frequency (1 up to 10) MHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) nF (0.2 - 0.2) %
  • frequency (1 up to 10) MHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) nF (0.01 - 0.01) %
  • frequency (50 up to 1000) Hz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) nF (0.01 - 0.01) %
  • frequency (50 up to 1000) Hz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) nF (0.003 - 0.003) %
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) nF (0.003 - 0.003) %
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) nF (0.015 - 0.015) %
  • frequency (1 up to 5) kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) nF (0.015 - 0.015) %
  • frequency (1 up to 5) kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) nF (0.02 - 0.02) %
  • frequency (5 up to 100) kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) nF (0.02 - 0.02) %
  • frequency (5 up to 100) kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) nF (0.05 - 0.05) %
  • frequency (0,05 up to 1) MHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) nF (0.05 - 0.05) %
  • frequency (0,05 up to 1) MHz
611-MP-C030, 611-MP-C041
9.11 (100 - 1000) nF (0.01 - 0.01) %
  • frequency (50 up to 1000) Hz
611-MP-C030, 611-MP-C041
9.11 (100 - 1000) nF (0.01 - 0.01) %
  • frequency (50 up to 1000) Hz
611-MP-C030, 611-MP-C041
9.11 (100 - 1000) nF (0.005 - 0.005) %
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (100 - 1000) nF (0.005 - 0.005) %
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (100 - 1000) nF (0.03 - 0.03) %
  • frequency (1 up to 100) kHz
611-MP-C030, 611-MP-C041
9.11 (100 - 1000) nF (0.03 - 0.03) %
  • frequency (1 up to 100) kHz
611-MP-C030, 611-MP-C041
9.11 (100 - 1000) nF (0.05 - 0.05) %
  • frequency (0,1 up to 1) MHz
611-MP-C030, 611-MP-C041
9.11 (100 - 1000) nF (0.05 - 0.05) %
  • frequency (0,1 up to 1) MHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) μF (0.01 - 0.01) %
  • frequency (50 up to 1000) Hz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) μF (0.01 - 0.01) %
  • frequency (50 up to 1000) Hz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) μF (0.005 - 0.005) %
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) μF (0.005 - 0.005) %
  • frequency 1 kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) μF (0.006 - 0.006) %
  • frequency (1 up to 5) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) μF (0.006 - 0.006) %
  • frequency (1 up to 5) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) μF (0.008 - 0.008) %
  • frequency (5 up to 10) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) μF (0.008 - 0.008) %
  • frequency (5 up to 10) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) μF (0.005 - 0.005) %
  • frequency (10 up to 100) kHz
611-MP-C030, 611-MP-C041
9.11 (1 - 10) μF (0.005 - 0.005) %
  • frequency (10 up to 100) kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) μF (0.05 - 0.05) %
  • frequency (50 up to 1000) Hz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) μF (0.05 - 0.05) %
  • frequency (50 up to 1000) Hz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) μF (0.006 - 0.006) %
  • frequency (1 up to 5) kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) μF (0.006 - 0.006) %
  • frequency (1 up to 5) kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) μF (0.018 - 0.018) %
  • frequency (5 up to 10) kHz
611-MP-C030, 611-MP-C041
9.11 (10 - 100) μF (0.018 - 0.018) %
  • frequency (5 up to 10) kHz
611-MP-C030, 611-MP-C041
9.11 (100 - 1000) μF (0.01 - 0.01) %
  • frequency (50 up to 200) Hz
611-MP-C030, 611-MP-C041
9.11 (100 - 1000) μF (0.01 - 0.01) %
  • frequency (50 up to 200) Hz
611-MP-C030, 611-MP-C041
9.11 (100 - 1000) μF (0.015 - 0.015) %
  • frequency (200 up to 1000) Hz
611-MP-C030, 611-MP-C041
9.11 (100 - 1000) μF (0.015 - 0.015) %
  • frequency (200 up to 1000) Hz
611-MP-C030, 611-MP-C041
9.11 (1 - 3) mF (0.02 - 0.02) %
  • frequency (50 up to 200) Hz
611-MP-C030, 611-MP-C041
9.11 (1 - 3) mF (0.02 - 0.02) %
  • frequency (50 up to 200) Hz
611-MP-C030, 611-MP-C041
9.11 (1 - 3) mF (0.025 - 0.025) %
  • frequency (200 up to 1000) Hz
611-MP-C030, 611-MP-C041
9.11 (1 - 3) mF (0.025 - 0.025) %
  • frequency (200 up to 1000) Hz
611-MP-C030, 611-MP-C041
9.11 (3 - 10) mF (0.03 - 0.03) %
  • frequency (50 up to 200) Hz
611-MP-C030, 611-MP-C041
9.11 (3 - 10) mF (0.03 - 0.03) %
  • frequency (50 up to 200) Hz
611-MP-C030, 611-MP-C041
Quantity: ztrátový činitel D
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.12 (1.0E-6 - 0.001) (3.0E-6 - 3.0E-6)
  • frequency 1 kHz
  • capacity C (1 up to 1000) pF
611-MP-C030, 611-MP-C041
9.12 (1.0E-6 - 0.001) (3.0E-6 - 3.0E-6)
  • frequency 1 kHz
  • capacity C (1 up to 1000) pF
611-MP-C030, 611-MP-C041
9.12 (1.0E-6 - 0.01) (1.0E-5 - 1.0E-5)
  • frequency 1 kHz
  • capacity C (1 up to 10) nF
611-MP-C030, 611-MP-C041
9.12 (1.0E-6 - 0.01) (1.0E-5 - 1.0E-5)
  • frequency 1 kHz
  • capacity C (1 up to 10) nF
611-MP-C030, 611-MP-C041
9.12 (1.0E-6 - 0.01) (4.0E-5 - 4.0E-5)
  • frequency 1 kHz
  • capacity C (10 up to 100) nF
611-MP-C030, 611-MP-C041
9.12 (1.0E-6 - 0.01) (4.0E-5 - 4.0E-5)
  • frequency 1 kHz
  • capacity C (10 up to 100) nF
611-MP-C030, 611-MP-C041
9.12 (1.0E-5 - 0.01) (0.0004 - 0.0004)
  • frequency 1 kHz
  • capacity C (100 up to 1000) nF
611-MP-C030, 611-MP-C041
9.12 (1.0E-5 - 0.01) (0.0004 - 0.0004)
  • frequency 1 kHz
  • capacity C (100 up to 1000) nF
611-MP-C030, 611-MP-C041
9.12 (0.001 - 0.01) (5.0E-6 - 5.0E-6)
  • frequency 1 kHz
  • capacity C (1 up to 1000) pF
611-MP-C030, 611-MP-C041
9.12 (0.001 - 0.01) (5.0E-6 - 5.0E-6)
  • frequency 1 kHz
  • capacity C (1 up to 1000) pF
611-MP-C030, 611-MP-C041
9.12 (0.01 - 0.1) (3.0E-5 - 3.0E-5)
  • frequency 1 kHz
  • capacity C (10 up to 10000) pF
611-MP-C030, 611-MP-C041
9.12 (0.01 - 0.1) (3.0E-5 - 3.0E-5)
  • frequency 1 kHz
  • capacity C (10 up to 10000) pF
611-MP-C030, 611-MP-C041
9.12 (0.01 - 0.1) (5.0E-5 - 5.0E-5)
  • frequency 1 kHz
  • capacity C (10 up to 100) nF
611-MP-C030, 611-MP-C041
9.12 (0.01 - 0.1) (5.0E-5 - 5.0E-5)
  • frequency 1 kHz
  • capacity C (10 up to 100) nF
611-MP-C030, 611-MP-C041
9.12 (0.1 - 1) (0.0003 - 0.0003)
  • frequency 1 kHz
  • capacity C (1 up to 100 000) pF
611-MP-C030, 611-MP-C041
9.12 (0.1 - 1) (0.0003 - 0.0003)
  • frequency 1 kHz
  • capacity C (1 up to 100 000) pF
611-MP-C030, 611-MP-C041
Quantity: AC resistance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.13 (10 - 100) mΩ (0.3 - 0.3) %
  • frequency (20 up to 1000) Hz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) mΩ (0.3 - 0.3) %
  • frequency (20 up to 1000) Hz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) mΩ (0.1 - 0.1) %
  • frequency 1 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) mΩ (0.1 - 0.1) %
  • frequency 1 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (=100*0.001 - 1) Ω (0.01 - 0.01) %
  • frequency 20 Hz up to 10 kHz
611-MP-C040, 611-MP-C041
9.13 (=100*0.001 - 1) Ω (0.01 - 0.01) %
  • frequency 20 Hz up to 10 kHz
611-MP-C040, 611-MP-C041
9.13 (=100*0.001 - 1) Ω (0.1 - 0.1) %
  • frequency 10 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (=100*0.001 - 1) Ω (0.1 - 0.1) %
  • frequency 10 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (1 - 1.0E+4) Ω (0.002 - 0.002) %
  • frequency 20 Hz up to 10 kHz
611-MP-C040, 611-MP-C041
9.13 (1 - 1.0E+4) Ω (0.002 - 0.002) %
  • frequency 20 Hz up to 10 kHz
611-MP-C040, 611-MP-C041
9.13 (1 - 1.0E+4) Ω (0.002 - 0.002) %
  • frequency 40 Hz up to 10 kHz
611-MP-C040, 611-MP-C041
9.13 (1 - 1.0E+4) Ω (0.002 - 0.002) %
  • frequency 40 Hz up to 10 kHz
611-MP-C040, 611-MP-C041
9.13 (1 - 1.0E+4) Ω (0.02 - 0.02) %
  • frequency 10 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (1 - 1.0E+4) Ω (0.02 - 0.02) %
  • frequency 10 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (1 - 1.0E+4) Ω (0.2 - 0.2) %
  • frequency (1 up to 10) MHz
611-MP-C040, 611-MP-C041
9.13 (1 - 1.0E+4) Ω (0.2 - 0.2) %
  • frequency (1 up to 10) MHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) kΩ (0.3 - 0.3) %
  • frequency (20 up to 50) Hz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) kΩ (0.3 - 0.3) %
  • frequency (20 up to 50) Hz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) kΩ (0.05 - 0.05) %
  • frequency 50 Hz up to 1 kHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) kΩ (0.05 - 0.05) %
  • frequency 50 Hz up to 1 kHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) kΩ (0.03 - 0.03) %
  • frequency 1 kHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) kΩ (0.03 - 0.03) %
  • frequency 1 kHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) kΩ (0.05 - 0.05) %
  • frequency (1 up to 10) kHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) kΩ (0.05 - 0.05) %
  • frequency (1 up to 10) kHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) kΩ (0.1 - 0.1) %
  • frequency 10 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) kΩ (0.1 - 0.1) %
  • frequency 10 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) kΩ (5 - 5) %
  • frequency (1 up to 10) MHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) kΩ (5 - 5) %
  • frequency (1 up to 10) MHz
611-MP-C040, 611-MP-C041
9.13 (0.1 - 1) MΩ (0.3 - 0.3) %
  • frequency (20 up to 50) Hz
611-MP-C040, 611-MP-C041
9.13 (0.1 - 1) MΩ (0.3 - 0.3) %
  • frequency (20 up to 50) Hz
611-MP-C040, 611-MP-C041
9.13 (0.1 - 1) MΩ (0.1 - 0.1) %
  • frequency 50 Hz up to 1 kHz
611-MP-C040, 611-MP-C041
9.13 (0.1 - 1) MΩ (0.1 - 0.1) %
  • frequency 50 Hz up to 1 kHz
611-MP-C040, 611-MP-C041
9.13 (0.1 - 1) MΩ (0.03 - 0.03) %
  • frequency 1 kHz
611-MP-C040, 611-MP-C041
9.13 (0.1 - 1) MΩ (0.03 - 0.03) %
  • frequency 1 kHz
611-MP-C040, 611-MP-C041
9.13 (0.1 - 1) MΩ (0.1 - 0.1) %
  • frequency 1 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (0.1 - 1) MΩ (0.1 - 0.1) %
  • frequency 1 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (0.1 - 1) MΩ (5 - 5) %
  • frequency (1 up to 10) MHz
611-MP-C040, 611-MP-C041
9.13 (0.1 - 1) MΩ (5 - 5) %
  • frequency (1 up to 10) MHz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (0.3 - 0.3) %
  • frequency (20 up to 50) Hz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (0.3 - 0.3) %
  • frequency (20 up to 50) Hz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (0.2 - 0.2) %
  • frequency (50 up to 100) Hz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (0.2 - 0.2) %
  • frequency (50 up to 100) Hz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (0.1 - 0.1) %
  • frequency 100 Hz up to 1 kHz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (0.1 - 0.1) %
  • frequency 100 Hz up to 1 kHz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (0.03 - 0.03) %
  • frequency 1 kHz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (0.03 - 0.03) %
  • frequency 1 kHz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (0.1 - 0.1) %
  • frequency 1 kHz up to 5 kHz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (0.1 - 0.1) %
  • frequency 1 kHz up to 5 kHz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (0.3 - 0.3) %
  • frequency 5 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (0.3 - 0.3) %
  • frequency 5 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (5 - 5) %
  • frequency 1 MHz up to 10 MHz
611-MP-C040, 611-MP-C041
9.13 (1 - 10) MΩ (5 - 5) %
  • frequency 1 MHz up to 10 MHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) MΩ (0.3 - 0.3) %
  • frequency (20 up to 50) Hz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) MΩ (0.3 - 0.3) %
  • frequency (20 up to 50) Hz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) MΩ (0.2 - 0.2) %
  • frequency (50 up to 100) Hz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) MΩ (0.2 - 0.2) %
  • frequency (50 up to 100) Hz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) MΩ (0.1 - 0.1) %
  • frequency 100 Hz up to 1 kHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) MΩ (0.1 - 0.1) %
  • frequency 100 Hz up to 1 kHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) MΩ (0.03 - 0.03) %
  • frequency 1 kHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) MΩ (0.03 - 0.03) %
  • frequency 1 kHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) MΩ (0.1 - 0.1) %
  • frequency (1 up to 5) kHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) MΩ (0.1 - 0.1) %
  • frequency (1 up to 5) kHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) MΩ (0.3 - 0.3) %
  • frequency 5 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
9.13 (10 - 100) MΩ (0.3 - 0.3) %
  • frequency 5 kHz up to 1 MHz
611-MP-C040, 611-MP-C041
Quantity: inductance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.14 (10 - 100) mH (0.0015 - 0.0015) %
  • frequency 1 kHz
611-MP-C099, 611-MP-C041
9.14 (10 - 100) mH (0.0015 - 0.0015) %
  • frequency 1 kHz
611-MP-C099, 611-MP-C041
9.14 (1 - 10) μH (0.1 - 0.1) %
  • frequency 1 kHz up to 1 MHz
611-MP-C099, 611-MP-C041
9.14 (1 - 10) μH (0.1 - 0.1) %
  • frequency 1 kHz up to 1 MHz
611-MP-C099, 611-MP-C041
9.14 (10 - 100) μH (0.3 - 0.3) %
  • frequency 50 Hz up to 200 Hz
611-MP-C099, 611-MP-C041
9.14 (10 - 100) μH (0.3 - 0.3) %
  • frequency 50 Hz up to 200 Hz
611-MP-C099, 611-MP-C041
9.14 (10 - 100) μH (0.015 - 0.015) %
  • frequency 200 Hz up to 1000 Hz
611-MP-C099, 611-MP-C041
9.14 (10 - 100) μH (0.015 - 0.015) %
  • frequency 200 Hz up to 1000 Hz
611-MP-C099, 611-MP-C041
9.14 (0.1 - 1) mH (0.3 - 0.3) %
  • frequency 20 Hz up to 50 Hz
611-MP-C099, 611-MP-C041
9.14 (0.1 - 1) mH (0.3 - 0.3) %
  • frequency 20 Hz up to 50 Hz
611-MP-C099, 611-MP-C041
9.14 (0.1 - 1) mH (0.015 - 0.015) %
  • frequency 50 Hz up to 1000 Hz
611-MP-C099, 611-MP-C041
9.14 (0.1 - 1) mH (0.015 - 0.015) %
  • frequency 50 Hz up to 1000 Hz
611-MP-C099, 611-MP-C041
9.14 (0.1 - 1) mH (0.01 - 0.01) %
  • frequency 1 kHz up to 5 kHz
611-MP-C099, 611-MP-C041
9.14 (0.1 - 1) mH (0.01 - 0.01) %
  • frequency 1 kHz up to 5 kHz
611-MP-C099, 611-MP-C041
9.14 (1 - 10) mH (0.3 - 0.3) %
  • frequency 20 Hz up to 50 Hz
611-MP-C099, 611-MP-C041
9.14 (1 - 10) mH (0.3 - 0.3) %
  • frequency 20 Hz up to 50 Hz
611-MP-C099, 611-MP-C041
9.14 (1 - 10) mH (0.15 - 0.15) %
  • frequency 50 Hz up to 200 Hz
611-MP-C099, 611-MP-C041
9.14 (1 - 10) mH (0.15 - 0.15) %
  • frequency 50 Hz up to 200 Hz
611-MP-C099, 611-MP-C041
9.14 (1 - 10) mH (0.05 - 0.05) %
  • frequency (10 up to 1000) MHz
611-MP-C099, 611-MP-C041
9.14 (1 - 10) mH (0.05 - 0.05) %
  • frequency (10 up to 1000) MHz
611-MP-C099, 611-MP-C041
9.14 (10 - 100) H (0.3 - 0.3) %
  • frequency 20 Hz up to 50 Hz
611-MP-C099, 611-MP-C041
9.14 (10 - 100) H (0.3 - 0.3) %
  • frequency 20 Hz up to 50 Hz
611-MP-C099, 611-MP-C041
9.14 (10 - 100) H (0.1 - 0.1) %
  • frequency 50 Hz up to 1 kHz
611-MP-C099, 611-MP-C041
9.14 (10 - 100) H (0.1 - 0.1) %
  • frequency 50 Hz up to 1 kHz
611-MP-C099, 611-MP-C041
9.14 (10 - 100) H (0.05 - 0.05) %
  • frequency 1 kHz up to 100 kHz
611-MP-C099, 611-MP-C041
9.14 (10 - 100) H (0.05 - 0.05) %
  • frequency 1 kHz up to 100 kHz
611-MP-C099, 611-MP-C041
9.14 (100 - 1000) H (0.3 - 0.3) %
  • frequency 20 Hz up to 50 Hz
611-MP-C099, 611-MP-C041
9.14 (100 - 1000) H (0.3 - 0.3) %
  • frequency 20 Hz up to 50 Hz
611-MP-C099, 611-MP-C041
9.14 (100 - 1000) H (0.1 - 0.1) %
  • frequency 50 Hz up to 10 kHz
611-MP-C099, 611-MP-C041
9.14 (100 - 1000) H (0.1 - 0.1) %
  • frequency 50 Hz up to 10 kHz
611-MP-C099, 611-MP-C041
Quantity: current
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.21 (1 - 1000) A (0.8 - 0.8) %
  • frequency 0 Hz
131-MP-C006
9.21 (1 - 1000) A (0.5 - 0.5) %
  • frequency 50 Hz
131-MP-C006
Quantity: insulation resistance
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (0.01 - 100) MΩ (0.0012 - 0.0012) % 131-MP-C006
9.21 (0.1 - 1) GΩ (0.0017 - 0.0017) % 131-MP-C006
9.21 (1 - 10) GΩ (0.0017 - 0.0086) % 131-MP-C006
9.21 (10 - 100) GΩ (0.0086 - 0.034) % 131-MP-C006
9.21 (0.1 - 1) TΩ (0.034 - 0.27) % 131-MP-C006
9.21 (1.0E+10 - 1) GΩ (0.02 - 0.02) % 131-MP-C006
9.21 (1 - 10) GΩ (1 - 1) % 131-MP-C006
9.21 (0.35 - 100) GΩ (1.2 - 1.5) % 131-MP-C006
9.21 (0.1 - 1) TΩ (2.5 - 2.5) % 131-MP-C006
9.21 (1 - 10) TΩ (4 - 4) % 131-MP-C006
9.21 (100 - 100) MΩ (0.002 - 0.002) % 131-MP-C006
9.21 (1 - 1) GΩ (0.003 - 0.003) % 131-MP-C006
Quantity: ochranná smyčka, impedance sítě a zemní smyčka
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (25 - 25) mΩ (5 - 5) mΩ 131-MP-C006
9.21 (50 - 50) mΩ (5 - 5) mΩ 131-MP-C006
9.21 (100 - 100) mΩ (5 - 5) mΩ 131-MP-C006
9.21 (330 - 330) mΩ (7 - 7) mΩ 131-MP-C006
9.21 (500 - 500) mΩ (8 - 8) mΩ 131-MP-C006
9.21 (1 - 1) Ω (10 - 10) mΩ 131-MP-C006
9.21 (1.8 - 1.8) Ω (18 - 18) mΩ 131-MP-C006
9.21 (5 - 5) Ω (30 - 30) mΩ 131-MP-C006
9.21 (10 - 10) Ω (60 - 60) mΩ 131-MP-C006
9.21 (18 - 18) Ω (100 - 100) mΩ 131-MP-C006
9.21 (50 - 50) Ω (300 - 300) mΩ 131-MP-C006
9.21 (100 - 100) Ω (500 - 500) mΩ 131-MP-C006
9.21 (180 - 180) Ω (1 - 1) Ω 131-MP-C006
9.21 (500 - 500) Ω (2.5 - 2.5) Ω 131-MP-C006
9.21 (1 - 1) kΩ (5 - 5) Ω 131-MP-C006
9.21 (1.8 - 1.8) kΩ (10 - 10) Ω 131-MP-C006
Quantity: RCD trip current
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (3 - 3000) mA (0.02 - 0.02) % 131-MP-C006
9.21 (3 - 3000) mA (1 - 1) % 131-MP-C006
Quantity: RCD trip time
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (10 - 5000) ms (0,02%+0,25ms - 0,02%+0,25ms) 131-MP-C006
9.21 (10 - 5000) ms (0.05 - 0.05) ms 131-MP-C006
Quantity: leakage current passive
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (0.1 - 30) mA (0,3%+2mA - 0,3%+2mA) 131-MP-C006
Quantity: leakage current differential
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (0.1 - 30) mA (0,3%+2mA - 0,3%+2mA) 131-MP-C006
Quantity: leakage current substitute
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (0.1 - 30) mA (0,3%+2mA - 0,3%+2mA) 131-MP-C006
Quantity: leakage current active
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.21 (0.1 - 30) mA (0,3%+1mA - 0,3%+1mA) 131-MP-C006
9.21 (0.1 - 30) mA (0.055 - 0.055) % 131-MP-C006
Quantity: high voltage
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.21 (0 - 10) kV (0,3%+5V - 0,3%+5V)
  • frequency 0 Hz
131-MP-C006
9.21 (0 - 10) kV (0,5%+5V - 0,5%+5V)
  • frequency 50 Hz
131-MP-C006
Quantity: high DC voltage: meters
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
HVC02 (1 - 100) kV (80 - 700) V
  • room temperature 23 °C
801-MP-C702
Quantity: high voltage impedance: capacitance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
HVC04a (10 - 1.0E+6) pF (250 - 250) µF/F
  • voltage 0,1 kV to 400 kV
  • frequency 50 Hz
801-MP-C703
Quantity: High voltage impedance: dissipation factor for capacitance
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
HVC04b (5.0E-5 - 0.1) (3.0E-5 - 0.003)
  • voltage up to 400 kV
  • frequency 50 Hz
801-MP-C703
Quantity: voltage transformer: ratio error
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
HVC11a (0 - 20) % (0.006 - 0.2) %
  • voltage ratio 100/5 V/V to 400/250 kV/V
  • frequency 50 Hz
817-MP-C701
Quantity: voltage transformer: phase displacement
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
HVC11b (0 - 20) crad (0.006 - 0.2) crad
  • voltage ratio 100/5 V/V to 400/250 kV/V
  • frequency 50 Hz
817-MP-C701
Quantity: current transformer: ratio error
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
HVC24a (0 - 20) % (0.002 - 0.2) %
  • current ratio 0.5/5 A/A to 5000/5 A/A and 5/1 A/A to 5000/1 A/A
  • frequency 50 Hz
817-MP-C701
Quantity: current transformer: phase displacement
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
HVC24b (0 - 20) crad (0.002 - 0.2) crad
  • current ratio 0.5/5 A/A to 5000/5 A/A and 5/1 A/A to 5000/1 A/A
  • frequency 50 Hz
817-MP-C701
Quantity: phase angle: meters
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
SIG04 (0 - 360) ° (0.01 - 0.5) °
  • frequency 1 Hz to 10 MHz
  • voltage 0.01 V to 100 V
817-MP-C701
Quantity: magnetic fields below 50 kHz: magnetic flux
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
EMF03a (0.1 - 100) mWb (10 - 10) 0.001 817-MP-C610
EMF03b (2 - 100) mWb (0,24 - 1) 0.001
  • magnetic flux per unit current 1 mWb/A to 100 mWb/A
817-MP-C601
Quantity: magnetic fields below 50 kHz: DC magnetic flux density
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
EMF04 (5.0E-5 - 2) T (5 - 5) 0.001
  • homogeneity of magnetic flux density 0 %/cm to 0.01 %/cm
817-MP-C609
Quantity: magnetic fields below 50 kHz: AC magnetic flux density
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
EMF05 (0.005 - 10) mT (6 - 15) 0.001
  • frequency 10 Hz to 50 kHz
817-MP-C608
Quantity: magnetic fields below 50 kHz: turn area
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
EMF08a (0.01 - 10) Wb/T (2 - 2) 0.001
  • magnetic flux 1 mWb to 100 mWb
817-MP-C603
EMF08b (0.01 - 1) Wb/T (5 - 5) 0.001
  • frequency 40 Hz to 1000 Hz
817-MP-C603
Quantity: magnetic fields below 50 kHz: DC magnetic flux density per unit current
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
EMF09a (0.5 - 50) mT/A (0,07 - 0,1) 0.001
  • magnetic flux density 0.5 mT to 100 mT
817-MP-C602
Quantity: magnetic fields below 50 kHz: AC magnetic flux density per unit current
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
EMF09b (0.05 - 10) mT/A (0,6 - 5) 0.001
  • frequency 40 Hz to 20000 Hz
817-MP-C603
Quantity: Soft magnetic sheet and powder materials: specific total power loss
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
MAT06 (0.2 - 20) W/kg (5 - 5) 0.001
  • frequency 50 Hz to 60 Hz
  • polarisation 0,3 T to 1,7 T
817-MP-C604
Quantity: Soft magnetic sheet and powder materials: peak value of AC magnetic polarisation
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
MAT08 (0.1 - 1.9) T (5 - 5) 0.001
  • frequency 50 Hz
817-MP-C604
Quantity: Soft magnetic sheet and powder materials: peak value of magnetic field strength
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
MAT09 (0.03 - 10) kA/m (5 - 5) 0.001
  • frequency 50 Hz
  • polarisation 0,1 T to 1,9 T
817-MP-C604
Quantity: Soft magnetic sheet and powder materials: RMS value of magnetic field strength
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
MAT10 (0.03 - 10) kA/m (5 - 5) 0.001
  • frequency 50 Hz
  • polarisation 0,1 T to 1,9 T
817-MP-C604
Quantity: Soft magnetic sheet and powder materials: specific apparent power
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
MAT11 (1 - 100) VA/kg (30 - 30) 0.001
  • frequency 50 Hz
  • polarisation 0,3 T to 1,7 T
817-MP-C604
Quantity: Soft magnetic bulk materials: magnetic saturation polarization
Interní identifikátor Range Calibration and measurement capabilities Procedures
MAT20 (0.2 - 5) Am2/kg (15 - 15) 0.001 817-MP-C606
Quantity: Hard magnetic materials: remanent magnetic flux density
Interní identifikátor Range Calibration and measurement capabilities Procedures
MAT23 (0.1 - 1.3) T (15 - 15) 0.001 817-MP-C605
Quantity: Hard magnetic materials: coercive field strength (HCB, HCJ)
Interní identifikátor Range Calibration and measurement capabilities Procedures
MAT24 (30 - 400) kA/m (15 - 15) 0.001 817-MP-C605
Quantity: Hard magnetic material: maximum energy product (B·H)max
Interní identifikátor Range Calibration and measurement capabilities Procedures
MAT25 (100 - 500) kJ/m3 (25 - 25) 0.001 817-MP-C605
Quantity: AC current
Interní identifikátor Range Calibration and measurement capabilities Procedures
9.20 (1 - 10) kA (0.021 - 0.1) % 817-MP-C705
9.20 (1 - 10) kA (5 - 20) ꞌ 817-MP-C705
9.20 (1 - 30) kA (0.021 - 0.1) % 817-MP-C705
9.20 (1 - 30) kA (5 - 20) ꞌ 817-MP-C705
Quantity: magnetic flux density
Interní identifikátor Range Calibration and measurement capabilities Procedures
(1 - 2000) mT (0.21 - 0.21) % 817-MP-C607
Quantity: electromagnetic fields above 50 kHz: AC magnetic flux density
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
EMF14 (0.001 - 0.08) mT (20 - 20) 0.001
  • frequency 50 kHz to 100 kHz
817-MP-C608
Quantity: antenna factor
Interní identifikátor Range Calibration and measurement capabilities Measurement conditions Procedures
9.29 (-10 - 60) dB/m (2.8 - 2.8) dB
  • frequency 30 MHz up to 100 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (2.8 - 2.8) dB
  • frequency 100 MHz up to 300 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (3 - 3) dB
  • frequency 300 MHz up to 1000 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (2 - 2) dB
  • frequency 1000 MHz up to 18000 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (2.2 - 2.2) dB
  • frequency 30 MHz up to 100 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (1.5 - 1.5) dB
  • frequency 100 MHz up to 300 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (1.4 - 1.4) dB
  • frequency 300 MHz up to 1000 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (2 - 2) dB
  • frequency 1000 MHz up to 18000 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (3.3 - 3.3) dB
  • frequency 30 MHz up to 100 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (3.3 - 3.3) dB
  • frequency 100 MHz up to 300 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (3.5 - 3.5) dB
  • frequency 300 MHz up to 1000 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (2.2 - 2.2) dB
  • frequency 1000 MHz up to 18000 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (2.5 - 2.5) dB
  • frequency 30 MHz up to 100 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (1.7 - 1.7) dB
  • frequency 100 MHz up to 300 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (1.7 - 1.7) dB
  • frequency 300 MHz up to 1000 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (2.2 - 2.2) dB
  • frequency 1000 MHz up to 18000 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (2.1 - 2.1) dB
  • frequency 0,009 MHz up to 30 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (3.5 - 3.5) dB
  • frequency 30 MHz up to 1000 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (3.1 - 3.1) dB
  • frequency 1000 MHz up to 18000 MHz
851-MP-C004
9.29 (-10 - 60) dB/m (2.2 - 2.2) dB
  • frequency 0,01 MHz up to 30 MHz
851-MP-C004