You are here
View CMC
Field of measurement
- electricity and magnetism
Interní identifikátor
RF33
Quantity
- RF voltage and current: RF voltage sources
Instrument or artifact
- RF generators
Calibration and measurement capabilities
| Range | Calibration and measurement capabilities |
|---|---|
| 0.1 - 7 V | 4 - 11 mV/V |
Technical competence
- CIPM MRA
Guarantee of service
| Guarantee for service | Department |
|---|---|
| Ing. Karel Dražil | Unit of Primary Metrology of RF Electrical Quantities |
Measurement conditions
Method
| Number of procedure | Title of procedure |
|---|---|
| 113-MP-C010 | RF Power Standard (Calibration Faktor) |
| 113-MP-C011 | HF voltage and current: RF meters, RF sources |