You are here

CMC database

Field of measurement: length
Quantity: line spacing L
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
CMI/74 (0.01 - 200) mm Q[28; 0,377 L], L in mm nm 814-MP-C405
CMI/75 (200 - 500) mm Q[68; 0,213 L], L in mm nm 814-MP-C405
Field of measurement: length
Quantity: error of indicated [vertical size, displacement] L
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
CMI/15 (0 - 0.72) m Q[0,5; 0,8L], L in m µm 815-MP-C503
Quantity: face spacing L
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
CMI/22 (10 - 720) mm Q[0,3; 0,6L], L in mm nm 815-MP-C503
Quantity: diameter
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
CMI/30 (3 - 100) mm 0.5 µm 815-MP-C503
CMI/33 (3 - 150) mm 0.5 µm 815-MP-C503
Quantity: tloušťka D
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
CMI/31 (0.003 - 0.5) m Q[0,8; 1,3D], D in m µm 815-MP-C503
CMI/34 (0.0003 - 0.5) m Q[0,8; 1,3D], D in m µm 815-MP-C503
CMI/36 (0.001 - 0.5) m Q[0,8; 1,3D], D in m µm 815-MP-C503
Quantity: external cylinder
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
CMI/48 (0 - 0.5) mm Q[0,8; 1,3D], D in m µm
  • cylinder diameter D up to 0.5 m
815-MP-C503
Quantity: internal cylinder
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
CMI/49 (0 - 0.5) mm Q[0,8; 1,3D], D in m µm
  • cylinder diameter D up to 0.5 m
815-MP-C503
Quantity: roundness
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
CMI/50 (0 - 0.5) mm Q[0,8;1,3D], D in m µm
  • sphere diameter D up to 0.5 m
815-MP-C503
Quantity: centre coordinates [hole, bore]
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
CMI/59 (100 x 100 - 700 x 700) mm x mm Q[0,8;1,1L], L in m µm
  • L is centre distance [m] 
815-MP-C503
CMI/60 (100 - 700) mm Q[0,5; 0,8L], L in m µm
  • L is centre distance [m] 
815-MP-C503
Quantity: error of indicated location
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
CMI/61 (0 - 700) mm Q[0,5; 0,8L], L in m µm
  • measured distance L up to 30 m
815-MP-C503
Quantity: 3-D size, shape
Internal identifier Range Calibration and measurement capabilities Procedure Note to procedure
CMI/62 (3 - 100) mm 0.25 µm 815-MP-C503
Quantity: central length
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
1.5 (0 - 20) m 0,01+0,2×L µm 633-MP-C006
1.12 (0.4 - 2.5) m Q(0,6 + 0,8×L) µm 815-MP-C501 VDI/VDE 2617-5, ISO 10360-2
1.12 (0 - 30) m Q(0,01; 0,4×L; 0,1aL) µm 815-MP-C501 VDI/VDE 2617-5, ISO 10360-2
1.12 (0.3 - 1) m 0,3;0,6×L µm
  • thermal expansion α (0..15)E-6/K
815-MP-C501 VDI/VDE 2617-5, ISO 10360-2
1.12 (0.01 - 2.5) m Q(0,8; 1,4×L) µm 815-MP-C501 VDI/VDE 2617-5, ISO 10360-2
1.12 (0 - 1.4) m Q (0,2; 0,8×L) µm 815-MP-C501 VDI/VDE 2617-5, ISO 10360-2
1.12 (0 - 0.2) m Q(0,5 + 0,8×L) µm 815-MP-C501 VDI/VDE 2617-5, ISO 10360-2
1.13 (0 - 1020) mm U3: (0,6 + 0,8×L) µm 815-MP-C503
1.14 (0.3 - 30) m Q(100;3×L) µm 815-MP-C510
1.14 (0 - 300) m Q(20;20×L) µm 815-MP-C510
1.15 (0 - 1020) mm Q (0,2; 0,8×L) µm 815-MP-C511
1.20 (0 - 1800) mm 15 µm 815-MP-C502
1.20 (0 - 1800) mm 13 µm 815-MP-C502
Field of measurement: plane angle
Quantity: squareness
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
CMI/45 (90 - 90) ° 0.5 "
  • uncertainty valid for 500 mm size 
815-MP-C503
CMI/46 (90 - 90) ° 0.5 "
  • uncertainty valid for 500 mm size 
815-MP-C503
Field of measurement: electricity and magnetism
Quantity: high DC voltage: meters
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC02 (1 - 100) kV (80 - 700) V
  • room temperature 23 °C
801-MP-C702
Quantity: high voltage impedance: capacitance
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC04a (10 - 1.0E+6) pF (250 - 250) µF/F
  • voltage 0,1 kV to 400 kV
  • frequency 50 Hz
801-MP-C703
Quantity: High voltage impedance: dissipation factor for capacitance
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC04b (5.0E-5 - 0.1) (3.0E-5 - 0.003)
  • voltage up to 400 kV
  • frequency 50 Hz
801-MP-C703
Quantity: voltage transformer: ratio error
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC11a (0 - 20) % (0.006 - 0.2) %
  • voltage ratio 100/5 V/V to 400/250 kV/V
  • frequency 50 Hz
817-MP-C701
Quantity: voltage transformer: phase displacement
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC11b (0 - 20) crad (0.006 - 0.2) crad
  • voltage ratio 100/5 V/V to 400/250 kV/V
  • frequency 50 Hz
817-MP-C701
Quantity: current transformer: ratio error
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC24a (0 - 20) % (0.002 - 0.2) %
  • current ratio 0.5/5 A/A to 5000/5 A/A and 5/1 A/A to 5000/1 A/A
  • frequency 50 Hz
817-MP-C701
Quantity: current transformer: phase displacement
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
HVC24b (0 - 20) crad (0.002 - 0.2) crad
  • current ratio 0.5/5 A/A to 5000/5 A/A and 5/1 A/A to 5000/1 A/A
  • frequency 50 Hz
817-MP-C701
Quantity: phase angle: meters
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
SIG04 (0 - 360) ° (0.01 - 0.5) °
  • frequency 1 Hz to 10 MHz
  • voltage 0.01 V to 100 V
817-MP-C701
Quantity: magnetic fields below 50 kHz: magnetic flux
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF03a (0.1 - 100) mWb (10 - 10) 0.001 817-MP-C610
EMF03b (2 - 100) mWb (0,24 - 1) 0.001
  • magnetic flux per unit current 1 mWb/A to 100 mWb/A
817-MP-C601
Quantity: magnetic fields below 50 kHz: DC magnetic flux density
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF04 (5.0E-5 - 2) T (5 - 5) 0.001
  • homogeneity of magnetic flux density 0 %/cm to 0.01 %/cm
817-MP-C609
Quantity: magnetic fields below 50 kHz: AC magnetic flux density
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF05 (0.005 - 10) mT (6 - 15) 0.001
  • frequency 10 Hz to 50 kHz
817-MP-C608
Quantity: magnetic fields below 50 kHz: turn area
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF08a (0.01 - 10) Wb/T (2 - 2) 0.001
  • magnetic flux 1 mWb to 100 mWb
817-MP-C603
EMF08b (0.01 - 1) Wb/T (5 - 5) 0.001
  • frequency 40 Hz to 1000 Hz
817-MP-C603
Quantity: magnetic fields below 50 kHz: DC magnetic flux density per unit current
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF09a (0.5 - 50) mT/A (0,07 - 0,1) 0.001
  • magnetic flux density 0.5 mT to 100 mT
817-MP-C602
Quantity: magnetic fields below 50 kHz: AC magnetic flux density per unit current
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
EMF09b (0.05 - 10) mT/A (0,6 - 5) 0.001
  • frequency 40 Hz to 20000 Hz
817-MP-C603
Quantity: Soft magnetic sheet and powder materials: specific total power loss
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
MAT06 (0.2 - 20) W/kg (5 - 5) 0.001
  • frequency 50 Hz to 60 Hz
  • polarisation 0,3 T to 1,7 T
817-MP-C604
Quantity: Soft magnetic sheet and powder materials: peak value of AC magnetic polarisation
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
MAT08 (0.1 - 1.9) T (5 - 5) 0.001
  • frequency 50 Hz
817-MP-C604
Quantity: Soft magnetic sheet and powder materials: peak value of magnetic field strength
Internal identifier Range Calibration and measurement capabilities Conditions of measurement Procedure Note to procedure
MAT09 (0.03 - 10) kA/m (5 - 5) 0.001
  • frequency 50 Hz
  • polarisation 0,1 T to 1,9 T
817-MP-C604

Pages